AAC/AAAC/ABC/ACSR CABLE avilable ,all kind of sizes are available !...

ABC Cable - Aerial Bundled Cable

 Product Description

1. Application of Service Drop Cable: Service Drop Cable(ABC CABLE) are mainly used for electric power tranmission, rebuiding of urban and forest regions. They can improves safety and reliance of electrified wire netting. 2. Type of Service Drop Cable: Service Drop Cable(ABC CABLE) covers mainly three types: Duplex Service Drop Triplex Service Drop Quadruplex Service Drop The cable can be produced whose construction is phase conductor with neutral bare conductor or phase conductor with insulated neutral conductor, etc. And we can still produce the cables according to the request of customers. 3. Detaild Introduction of Service Drop Cable 3.1 Duplex Service Drop Applications To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum. Construction Concentic strand or cmpressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger. 3.2 Triplex Service Drop Applications To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for PE insulation or 90 maximum for XLPE insulation. Construction Concentic strand or cmpressed 1350-H19 conductor, polyethylene or cross linked polyethylene insulation, concentric strand AAC, ACSR, or 6201 alloy nertral messenger. 3.3 Quadruplex Service Drop Applications Used to supply 3 phase power, usually from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for PE insulated conductors or 90 for XLPE insulated conductors. Construction Conductors are concentrically standed, compressed 1350-H19 aluminium. Insulated with either polyethylene or XLPE. Neutral messengers aer concentrically stranded 6210 AAAC, AAC or ACSR.

 

 

Standards: 1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes. 2. B-231 Aluminum Conductors, Concentric-Lay-Stranded. 3. B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR). 4. B-399 Concentric-Lay_Stranded 6201-T81 Aluminum Alloy Conductors. 5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR). 6. Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474

Item# 

Phase Conductor Size AWG 

PhaseConductorStranding 

Phase ConductorInsulation Thickness 

Bare NeutralMessengerSize AWG 

BareNeutral Strand 

Bare Neutral messenger Breaking Strength 

Weight Per 1000ft - XLP 

Weight Per 1000ft - Poly 

Rating - XLP 

Rating-Poly 

Pekingese 

Solid 

45 mls 

7/w 

563 Lbs 

63.5 Lbs 

61.7 Lbs 

70 Amps 

70 Amps 

Collie 

7/w 

45 mls 

7/w 

563 Lbs 

66.8 Lbs 

63.1 Lbs 

70 Amps 

70 Amps 

Dachshund 

Solid 

45 mls 

7/w 

881 Lbs 

95.5 Lbs 

93.4 Lbs 

90 Amps 

90 Amps 

Spaniel 

7/w 

45 mls 

7/w 

881 Lbs 

100.5 Lbs 

95.4 Lbs 

90 Amps 

90 Amps 

Doberman 

7/w 

45 mls 

7/w 

1350 Lbs 

152.7 Lbs 

145.7 Lbs 

120 Amps 

120 Amps 

Malemute 

1/0 

19/w 

60 mls 

1/0 

7/w 

1990 Lbs 

242.6 Lbs 

234.2 Lbs 

160 Amps 

160 Amps 